How to install the STF Teststand Software
You need local admin permission to install software on GSI Windows -PC's.
- Mount network disk:
\\winfilesvh.gsi.de\MT
-
Navigate to ==\\wincontrols.gsi.de\data\NI\Software\Developer_Suite_2015_DS2
<br />You find the NI Development Software in this folder.
- Copy
DSC 2015 RunTime.zip
to a local drive and unzip.
- Install the necessary LabVIEW Runtime software for the Data Logging and Supervisory Control Module:
your-unzip-folder\Setup.exe
- =Mount network disk:
\\wincontrols.gsi.de\data\STF=
-
Navigate to ==Installer
<br />You find a collection of installers in this folder.
- Install the necessary LabVIEW Runtime software and drivers:
.\STF Driver Installer\Volume\Setup.exe==
-
Install the STF Teststand software: ==STF-Installer-k-l-m\Volume\Setup.exe
(Version k: Major, l:Minor ,m: Fix)
- Edit the
C:\Program Files (x86)\STF\STF.ini
and modify it to your needs. *Make sure that it is set to Read-Only.
- Configure the Windows Firewall if you want to access the historical data, alarms and messages. Refer to eLog for details.
--
HolgerBrand - 21 Jul 2016
Please note: When using STF.exe for KIT Quench Detection applications the
KIT-calibration file has to be placed in following directory:
"C:\STF\Configuration\Calibration\KIT-Calibration.ini"
In the case this directory path doesn't exist it has to be created (admin permission required!).