Main Quadrupole Magnets, rms random error amplitudes:
  • d(b2)=24e-4, which corresponds to dK1n=5.17e-4(1/m2)
  • d(a2)=20e-4, which corresponds to dK1s=4.3e-4(1/m2)

Closed orbit distortions: dx_rms=2mm, dy_rms=1mm.

Chromaticity sextupoles are off.

The effect of the two long quadrupoles (L=1.76m) is neglected.

The aperture: in dipoles, xmax=±0.06m, ymax=±0.034m

This topic: SIS100BD > WebHome > SIS100Data > AdditionalSetforSimulations
Topic revision: 2020-04-24, VladimirKornilov